Your Product Has Been Added to Cart
View Cart
The Shurflo 2088 Series is a go-to 12-volt diaphragm pump for spot sprayers, skid sprayers and UTV rigs used by pest and weed professionals. The 2088-343-135 is an automatic-demand model. A built-in pressure switch turns the pump on when you open the spray valve and shuts it off at 45 PSI when you close it, so there's no separate on/off switching while you work. It's self-priming up to 12 vertical feet, can run dry without damage, and has a built-in check valve to keep liquid from flowing back into the tank.
Pumps that have been installed are not eligible for return, refund or exchange. We do this to ensure all our customers receive pumps in brand-new condition.
| Model | Shurflo 2088-343-135 |
| Voltage | 12V DC |
| Max Flow | 3.0 GPM |
| Shut-Off Pressure | 45 PSI (automatic demand switch) |
| Ports | 1/2" male threaded, inlet and outlet |
| Self-Priming | Up to 12 vertical feet |
| Run Dry | Yes, without damage |
| Check Valve | Built in, prevents backflow into the tank |
| Wiring | Red (+) / black (−), #14 AWG or heavier; fuse per motor label |
From Shurflo's 2088 Series service kit chart. Call us at 602-371-1993 for parts not linked below.
| Part | Shurflo # |
| Complete pump head assembly | 94-236-11 |
| Pressure switch assembly | 94-230-36 |
| Check valve assembly | 94-237-05 |
| Upper housing | 94-231-30 |
| Valve assembly | 94-232-05 |
| Drive / diaphragm assembly | 94-238-03 |
| Motor | 11-111-00 |
My pump turns on and off rapidly while spraying. What's wrong?
That's called rapid cycling, and it happens when the flow is very low or the plumbing is restrictive, so the pump repressurizes faster than liquid leaves. Shurflo recommends reducing outlet restrictions or adding an accumulator. Frequent rapid cycling can damage the pump.
The pump won't shut off when I close the valve.
Check for leaks or air trapped in the outlet line, debris or swelling in the valves, loose pump head screws, and correct voltage at the pump. If the valves are worn, the 94-232-05 valve assembly is the fix. The pressure switch (94-230-36) may also need replacing.
The motor runs but nothing comes out.
Check the tank level, the inlet strainer, kinked or leaking inlet tubing, and debris in the pump valves. Also check for a cracked housing. The 94-231-30 upper housing replaces a cracked one.
Liquid is leaking from the bottom of the pump.
Shurflo says fluid at the bottom drain points to a punctured diaphragm. Replace it with the 94-238-03 drive/diaphragm assembly.
Can I pump any chemical?
Don't assume compatibility. Match your chemicals to the pump's materials, and never pump flammable liquids or run the pump in an explosive environment.

MODEL: 2088-343-135
$193.99
Add To Cart