Pumptec 212T-170 M8220 Pump and Motor 80130

SKU: 80130
MSRP: $628.96
Was: $525.99
Now: $472.99
(You save $155.97)
Adding to cart… The item has been added
Rating:
Reviews

Product Description

Pumptec 80130 212T-170/M8220 12V Pump & Motor

The genuine Pumptec 80130 212T-170/M8220 Pump & Motor Assembly is a professional-grade 12-volt electric plunger pump designed for compatible power sprayers and spray rig applications. Built with a hardcoat aluminum pump body, stainless steel plunger, and chemical-resistant Viton (FKM) O-rings, this assembly provides reliable pumping performance for demanding spray equipment.

The Pumptec 212T-170 delivers approximately 2.2 GPM at 100 PSI while drawing approximately 19.5 amps under Pumptec's published test conditions. Its four 1/4" NPT female ports provide two inlet and two outlet connection options for compatible plumbing configurations.

Whether you're replacing a worn-out pump or building a compatible 12V spray system, the 80130 provides a complete pump and motor assembly without requiring the purchase of the pump and motor separately.

Already own this pump? If the motor is working properly but the plunger seals are worn, you may be able to rebuild the existing pump instead. See our Pumptec 10021 KIT-A Plunger & Seal Repair Kit – 212T Viton.

Features & Benefits

12V Electric Operation: Designed for compatible battery-powered spray equipment and mobile spraying systems.

Professional Pumping Performance: Approximately 2.2 GPM at 100 PSI with the 0.170 cam configuration under published test conditions.

Hardcoat Aluminum Pump Body: Durable construction designed for demanding spray equipment applications.

Stainless Steel Internal Components: Stainless steel plunger and valves provide durability in compatible pumping applications.

Viton Seals: FKM O-rings provide chemical resistance for compatible spray solutions.

Serviceable Design: Replacement plunger, seal, and valve kits are available to help maintain the pump and extend its usable service life.

Specifications

Product Specifications
Manufacturer Pumptec
Part Number 80130
Pump Model 212T-170
Motor Model M8220
Voltage 12V DC
Performance at 100 PSI Approx. 2.2 GPM
Current at 100 PSI Approx. 19.5 Amps
Maximum Rated Pressure 200 PSI
Open Flow 2.94 GPM
Inlet Ports (2) 1/4" Female NPT
Outlet Ports (2) 1/4" Female NPT
Pump Body Hardcoat Aluminum
Plunger Material Stainless Steel
O-Ring Material Viton (FKM)
Maximum Fluid Temperature 140°F
What's Included Pump & Motor Assembly

Published performance is based on pumping water at room temperature with a 12V DC supply. Actual results vary with system conditions.

Repair Your Existing Pump or Replace It?

Pumptec's 212T design allows several internal components to be serviced rather than replacing the entire pump assembly. Choosing between a repair kit and a complete replacement depends on the condition of the motor, pump heads, valves, and internal seals.

Option 1: Rebuild Your Existing Pump

If your 212T motor operates normally but the pump is leaking around the plunger or has worn seals, rebuilding may be a more economical solution.

Shop Pumptec 10021 KIT-A Plunger & Seal Kit – 212T Viton

This repair kit includes one stainless steel plunger, two seal rings, two Viton O-rings, and two plunger guides. It does not include pump heads, valves, the motor, or the complete pump assembly.

Option 2: Replace the Complete Pump & Motor

If the motor has failed, the pump has substantial internal damage, or rebuilding is not practical, the Pumptec 80130 provides a complete replacement pump and motor assembly.

Important: Confirm the original pump model, voltage, cam configuration, port connections, and motor specifications before ordering. Not every Pumptec 212T configuration is interchangeable.

Installation & Maintenance

Electrical Supply: Use a properly sized 12V DC electrical system with suitable wiring and circuit protection according to Pumptec's installation instructions.

Inlet Plumbing: Maintain an adequate, unrestricted liquid supply. A clogged strainer or restricted suction line can cause cavitation and premature pump damage.

Pressure Control: Use an appropriate pressure regulation or bypass arrangement for the intended application. The pump's maximum pressure rating should not be treated as its required operating pressure.

Chemical Compatibility: Verify the compatibility of all wetted pump materials with the specific chemicals and concentrations being applied.

Maintenance Tip: Avoid running the pump dry, keep inlet filters clean, and inspect fittings, seals, and plumbing connections regularly to help extend pump service life.

Returns & Warranty

Important: Pumptec pumps that have been installed are not eligible for return or exchange through QSpray. Please verify compatibility before installation. Manufacturer warranty coverage is subject to Pumptec's terms and conditions.

View Pumptec Customer Support & Warranty Information

Manuals & Parts Diagrams

Download Pumptec 112T / 212T Owner's Manual & Parts Breakdown (PDF)

The manual includes installation, maintenance, and repair information, including the exploded 212T pump diagram and replacement kit identification.