Tank Calculations
To determine the number of Surge Busters for a particular size tank:
SurgeBuster 15" (for tanks with fills > 15")
1. Determine the tank capacity.
2. Divide the tank capacity by 32
3. This will give the number of units for that particular system.
4. Example: 525 gallons divided by 32 = 16.4
5. Round up to 17; Tank requires 17 units.
SurgeBuster 7" (for tanks with fills between 7" and 15")
1. Determine the tank capacity.
2. Divide the tank capacity by 30
3. This will give the number of units for that particular system.
4. Example: 225 gallons divided by 30 = 7.5
5. Round up to 8; Tank requires 8 units.
Note: The system should appear ½ to ¾ full when placed in tank.
Mini-Busters (for small tanks, usually < 25 gallons)
1. Determine the tank capacity.
2. Multiply # of gallons in tank by 15.
3. Example: 10 gallon tank x 15 = 150
4. Tank requires 150 units.
DO NOT USE MORE OR LESS THAN REQUIRED.
Click for Purchase Information